- In addition to digital, frequency and analog output signals, BLE mode has also been added to this sensor.
- Has OExiallBT6 X explosion protection certificate, CE and E-Mark certificate, Customs Union certificate, GOST-R certificate of conformity, measuring instrument certificate.
- It is now possible to set up and receive data through a mobile application. li>
- New housing
Additional glass-filled polyamide protective housing provides even greater resistance to external mechanical influences and system compromise.
Other benefits
- The measuring part of the sensor can be easily adapted to any tank depth.
- The fuel control sensor is simply set
- Galvanic isolation throughout the sensor body.
- Monitoring of connector opening and/or cable breakage.
- Extended analog range signal from 0.2 to 9 V.
- Operating temperature range from -60/+85 °C
* The sensor has no built-in power supply
Specs:
Power supply | 7 … 80 V*¹ |
Current draw, not more than 1 | 30 mA |
Measurement uncertainty in work area | < tdstyle="height: 27px; text-align: center;">no more than 1%|
Operating modes | digital, frequency, analog |
Digital mode:  ;wired - interface - communication protocol - communication speed - LLS output signal range< /td> | RS-485 LLS 19200 bps 0 … 4095 units |
Digital Mode: wireless (for use TD.150012.000-01**) | Bluetooth LE (BLE)** Escort BLE** |
Frequency mode: -output range | 300 … 4395Hz |
Analog mode: - output range | 0,2 … 9 B*² |
Receiver Sensitivity / Transmitter Power | -96 dBm** / 4 dBm** |
Working range frequencies (BLE) | 2.402-2.480 GHz** |
Sheath protection level by GOST 14254 | IP67 |
Protection against electric shock according to GOST 12.2.007.0< /td> | Class III |
Type of explosion protection | Type of protection intrinsically safe electrical circuit level "ia" | 0Ex ia IIB T6 X |
Working explosive mixture according to GOST R IEC 60079-20-1-2011 | categories IIA, IIB |
Explosive areas according to GOST IEC 60079-10 -1- 2011 | 0; 1 and 2 |
Operating environment: - ambient temperature - limiting ambient temperature - atmospheric pressure | - 45 ? /td> |
Dimensions, no more than mm | 80x80x(L+21) mm, where L – is the gauge length in mm |
Conventional Gauge Length | indicated on the label (pasted in the passport) |
Sensor length td> | 1500mm |
Weight, no more than kg | 0.35 + 0.4xL, where L – is the length of the gauge in meters |
< p>*1 - in order to comply with the certificate of conformity No. TS RU CRU.MYu62.V.00110/18 No. 0574797, the supply voltage should not exceed 40V.
*2 When connecting resistors in power supply circuit, the output signal range may differ significantly.
** - used for version TD.150012.000-01.